Pandemedica Germbuster
Touchless start/stop
Provides ease of operation and further decrease the risk of infection by contact.
Dental External Oral Suction Unit
Replaceable wide-mouth suction hood
Strong suction power, equipped with wide-mouth suction hood, collects the harmful particles immediately at the source, the patient's mouth, and increases the overall efficiency.
Activated carbon filter
Eliminates ozone generated by cold plasma ionizer and odor.
Segmented rotary arm
Provides user with maximum flexibility and ease of use.
Ultra Gel Microbial Air filter
Most efficient and complete air filtration based on UGMA technology enables excellent filtering of particles as small as 0.10 micron while maintaining low power usage by increased airflow with low pressure drop.
Cold Plasma Ionizer Purification
Completely eliminates germs and viruses.
Eliminates spray mist
Risk of infection is greatly reduced
Superb blower
Designed for non-stop use
Adjustable suction
Lets the user determine the suction
GermBuster eliminates dangers of spray mist
Everyday regular activities of dentists require the use of high-speed instruments. In the process, aerosols (spray mists) are formed. The aerosol emerging from the mouth of the patient is not homogeneous, it contains rebound cooling water, saliva, blood, microorganisms, viruses. And this mixture presents a high risk of infection. Dangers from the spray mist:
-
Spread of a contaminated spray mist cloud can be over a radius of several meters
-
Because of the mist particles, surfaces in the treatment area are contaminated.
-
High risk of infection for patients due to cross contaminations
-
Over 600 different types of bacteria can be detected in the human mouth which can be spread while dental work being done.
-
1 ml saliva contains about 10 million bacteria as well as viruses
-
During a 15-minute session without preventive measures, approx. 0.014–0.102 microliters of saliva is inhaled via the air by dental care specialists.
(Source: Bennet et al. British Dental Journal, Vol. 189 No. 12 (2000))
Spray mist suction is a safe solution
Without spray mist suction, the cooling water of the fast-running and ultrasonic instruments can cause contagious particle cloud to spread throughout the entire treatment room. With the suction power of around 4000 l/min, risk of infection is greatly reduced by eliminating these particles.
5 stage filtering processused in Pandemedica products
Sophisticated Ultra Gel Microbial Air filter
Filtron® F5 UGMA class 3-layer filter provides the highest performance microbial purification in the world and removes particles smaller than 0.10 microns (COVID-19 is 0.12 microns).
High technology air blowers
Powerful blowers provide continuous flow with high rates for quick air circulation in SafeAir and powerful suction in GermBuster
Cold Plasma Ionizer
Cold Plasma Ionizer Purification eliminates particles as small as 0.01 microns (viruses, odor molecules, cigarette smoke), increases overall system performance to 99.9%.
Activated Carbon filter against Ozone
Activated Carbon filter removes odors and ozone generated by Cold Plasma Ionizer. The output air conforms with EU regulations.
Dust Filter
Pre-filter removes dust, hair and other particles
Ultra Gel Microbial Air filter (UGMA)
It is the Gel air filter system which provides the highest performance pathogen purification in the world, while filtering particles which HEPA filters can't. Even high humidity conditions have no adverse effects on the UGMA filter.
-
Particle size retention at less than 0.10 micron marginally better than HEPA filter with 0.30 micron
-
99.7% high efficient to remove micro-particles (virus, bacteria, yeast, mold)
-
Unique gel composition of UGMA filter favors high humidity. While cellulose structure of HEPA filter does not.
-
Proven performance according to the EN 14683
-
Wide spectrum odor and gas retention potential
-
Low differential pressure provides high energy saving
-
Continuous high performance during lifetime
Pandemedica GermBuster eliminates airborne contaminants such as
Technical Specifications
Power requirements
Typical Energy Consumption
Weight, Device incl. filters
Suction flow
Noise Level
Fan motor
Control panel
Fan speed control
Air intake
Body Color / Handles Color
Body material.
Operating temperature / humidity
Electrical safety certification
System efficiency
Average Filter Life
Supplied accessories
Filter and disinfection Configuration
Total Number of Stages
Filter
Cold Plasma Ion Generator
Actived carbon filter
AC220V, 50/60 Hz
300 Watts
48 kg
up to 4200 L/min
Up to 60 dB
Сentrifugal, designed for non-stop use
Touchless start/stop, Adjustable fan speed
Manual
Segmentent rotary arm tube with removable hood
White / Black
Electrostatic powder coated steel
5° to 40°C / 5% to 95%
CE
99,9% high microorganism selectivity (virus, bacteria, yeast, mold) less than 0.10 microns
3 months
Power cord with plug, User manual
5
UGMA (Ultra Gel Microbial Air) Filter straining viruses, bacterias and other microorganisms
Killing viruses, bad smells, and bacterias on the air. Removes cigarette smoke.
Odor and gas filter (removes Ozone from air)