top of page

Pandemedica Germbuster

Touchless start/stop

Provides ease of operation and further decrease the risk of infection by contact.

Dental External Oral Suction Unit

Replaceable wide-mouth suction hood

Strong suction power, equipped with wide-mouth suction hood, collects the harmful  particles immediately at the source, the patient's mouth, and increases the overall efficiency.

Activated carbon filter

Eliminates ozone generated by cold plasma ionizer and odor.

Segmented rotary arm

Provides user with maximum flexibility and ease of use.

Ultra Gel Microbial Air filter

Most efficient and complete air filtration based on UGMA technology enables excellent filtering of particles as small as 0.10 micron while maintaining low power usage by increased airflow with low pressure drop.

Cold Plasma Ionizer Purification

Completely eliminates germs and viruses.

dent.png
GermsBuster_hires_transparent-bg.png
CardiAid-CT0207RF_with-Bag.png
InfarctHeartAttackIllustrationfromCytori

Eliminates spray mist
Risk of infection is greatly reduced

Superb blower
Designed for non-stop use

Adjustable suction

Lets the user determine the suction

GermBuster eliminates dangers of spray mist

Canva - A Dentist Checking On Her Patien

Everyday regular activities of dentists require the use of high-speed instruments. In the process, aerosols (spray mists) are formed. The aerosol emerging from the mouth of the patient is not homogeneous, it contains rebound cooling water, saliva, blood, microorganisms, viruses. And this mixture presents a high risk of infection. Dangers from the spray mist:
 

  • Spread of a contaminated spray mist cloud can be over a radius of several meters

  • Because of the mist particles, surfaces in the treatment area are contaminated.

  • High risk of infection for patients due to cross contaminations

  • Over 600 different types of bacteria can be detected in the human mouth which can be spread while dental work being done.

  • 1 ml saliva contains about 10 million bacteria as well as viruses

  • During a 15-minute session without preventive measures, approx. 0.014–0.102 microliters of saliva is inhaled via the air by dental care specialists.

(Source: Bennet et al. British Dental Journal, Vol. 189 No. 12 (2000))

Spray mist suction is a safe solution

Without spray mist suction, the cooling water of the fast-running and ultrasonic instruments can cause contagious particle cloud to spread throughout the entire treatment room. With the suction power of around 4000 l/min, risk of infection is greatly reduced by eliminating these particles.

GermsBuster-suction.webp

5 stage filtering processused in Pandemedica products

AirBlend_stages_01.webp
AirBlend_stages_02.webp
AirBlend_stages_03.webp
AirBlend_stages_04.webp
AirBlend_stages_05.webp

Sophisticated Ultra Gel Microbial Air filter

Filtron® F5 UGMA class 3-layer filter provides the highest performance microbial purification in the world and removes particles smaller than 0.10 microns (COVID-19 is 0.12 microns).

High technology air blowers

Powerful blowers provide continuous flow with high rates for quick air circulation in SafeAir and powerful suction in GermBuster

Cold Plasma Ionizer

Cold Plasma Ionizer Purification eliminates particles as small as 0.01 microns (viruses, odor molecules, cigarette smoke), increases overall system performance to 99.9%.

Activated Carbon filter against Ozone

Activated Carbon filter removes odors and ozone generated by Cold Plasma Ionizer. The output air conforms with EU regulations.

Dust Filter

Pre-filter removes dust, hair and other particles

Ultra Gel Microbial Air filter (UGMA)

It is the Gel air filter system which provides the highest performance pathogen purification in the world, while filtering particles which HEPA filters can't. Even high humidity conditions have no adverse effects on the UGMA filter.

  • Particle size retention at less than 0.10 micron marginally better than HEPA filter with 0.30 micron

  • 99.7% high efficient to remove micro-particles (virus, bacteria, yeast, mold)

  • Unique gel composition of UGMA filter favors high humidity. While cellulose structure of HEPA filter does not.

  • Proven performance according to the EN 14683

  • Wide spectrum odor and gas retention potential

  • Low differential pressure provides high energy saving

  • Continuous high performance during lifetime

layer.png
Pandemedica GermBuster eliminates airborne contaminants such as
brpic.png

Technical Specifications

Power requirements

Typical Energy Consumption

Weight, Device incl. filters

Suction flow

Noise Level

Fan motor

Control panel

Fan speed control

Air intake

Body Color / Handles Color

Body material.

Operating temperature / humidity

Electrical safety certification

System efficiency

Average Filter Life

Supplied accessories

Filter and disinfection Configuration

Total Number of Stages

Filter

Cold Plasma Ion Generator

Actived carbon filter

AC220V, 50/60 Hz

300 Watts

48 kg

up to 4200 L/min

Up to 60 dB

Сentrifugal, designed for non-stop use

Touchless start/stop, Adjustable fan speed

Manual

Segmentent rotary arm tube with removable hood

White / Black

Electrostatic powder coated steel

5° to 40°C / 5% to 95%

CE

99,9% high microorganism selectivity (virus, bacteria, yeast, mold) less than 0.10 microns

3 months

Power cord with plug, User manual

5

UGMA (Ultra Gel Microbial Air) Filter straining viruses, bacterias and other microorganisms

Killing viruses, bad smells, and bacterias on the air. Removes cigarette smoke.

Odor and gas filter (removes Ozone from air)